Conferencia

Pérez López, N.; De Luca, M.A.; Sivori, G.; Cymberknop, L.J.; Armentano, R.L.; Romero E.; Lepore N.; Brieva J.; Larrabide I.; et al.; Ministerio de Ciencia, Tecnologia e Innovacion Productiva (MinCyT); SIPAIM Foundation; Universidad Nacional de Colombia; Universidad Nacional del Centro de la Provincia de Buenos Aires (UNICEN); Universidad Panamericana "Real-time vascular response assessment by means of a dual pressure-diameter device: A preliminary study" (2017) 12th International Symposium on Medical Information Processing and Analysis, SIPAIM 2016. 10160
El editor no permite incluir ninguna versión del artículo en el Repositorio.
Consulte el artículo en la página del editor
Consulte la política de Acceso Abierto del editor

Abstract:

Introduction: Vascular reactivity (VR) can be defined as the arterial ability to react to vasoactive stimulus in terms of vasodilator or vasoconstrictor responses, where blood vessel tone is determined both by smooth muscle and endothelial functions (EF). Flow mediated dilation (FMD) and Peripheral Arterial Tonometry (PAT) measurements are recognized as the most relevant techniques for VR and EF evaluation. Objective: To design an integrated system for vascular analysis based on the limitations reported in FMD technique and incorporating PAT as a simultaneous measure. Materials and Methods: A complete software platform and a specific fastening system were proposed, in order to obtain simultaneous measurements of continuous arterial pressure (by applying the applanation tonometry technique) and continuous vessel diameter variations (by processing B-mode ultrasound images) at the same vascular site. Results: Beat to beat pressure-diameter loops were obtained, along with the assessment of stiffness indices and pulse transit time values. The volunteer who used the system felt comfortable and relaxed, unworried about making about involuntary movements Conclusion: A preliminary study was carried out using this new module designed for the acquisition, realtime processing, visualization and storage of vascular behavior related data. © 2017 SPIE.

Registro:

Documento: Conferencia
Título:Real-time vascular response assessment by means of a dual pressure-diameter device: A preliminary study
Autor:Pérez López, N.; De Luca, M.A.; Sivori, G.; Cymberknop, L.J.; Armentano, R.L.; Romero E.; Lepore N.; Brieva J.; Larrabide I.; et al.; Ministerio de Ciencia, Tecnologia e Innovacion Productiva (MinCyT); SIPAIM Foundation; Universidad Nacional de Colombia; Universidad Nacional del Centro de la Provincia de Buenos Aires (UNICEN); Universidad Panamericana
Filiación:Grupo de Investigación y Desarrollo en Bioingeniería, Facultad Regional Buenos Aires, Universidad Tecnológica Nacional, Argentina
Facultad de Ingeniería y Ciencias Exactas y Naturales, Universidad Favaloro, Buenos Aires, Argentina
Palabras clave:Applanation tonometry; Pressure-Diameter loop; Pulse transit time; Real-time system; Ultrasound; Vascular reactivity; Bioinformatics; Blood vessels; Data visualization; Digital storage; Interactive computer systems; Real time systems; Ultrasonics; Applanation tonometry; B-mode ultrasound images; Endothelial function; Flow mediated dilation; Involuntary movements; Peripheral arterial tonometry; Pulse transit time; Simultaneous measurement; Ultrasonic applications
Año:2017
Volumen:10160
DOI: http://dx.doi.org/10.1117/12.2257206
Título revista:12th International Symposium on Medical Information Processing and Analysis, SIPAIM 2016
Título revista abreviado:Proc SPIE Int Soc Opt Eng
ISSN:0277786X
CODEN:PSISD
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_0277786X_v10160_n_p_PerezLopez

Referencias:

  • Boutouyrie, P., Determinants of pulse wave velocity in healthy people and in the presence of cardiovascular risk factors: 'establishing normal and reference values' (2010) The Reference Values for Arterial Stiffness' Collaboration, European Heart Journal, 31 (19), pp. 2338-2350
  • Paini, A., Boutouyrie, P., Calvet, D., Tropeano, A.I., Laloux, B., Laurent, S., Carotid and aortic stiffness determinants of discrepancies (2006) Hypertension, 47 (3), pp. 371-376
  • Bussy, C., Boutouyrie, P., Lacolley, P., Challande, P., Laurent, S., Intrinsic stiffness of the carotid arterial wall material in essential hypertensives (2000) Hypertension, 35 (5), pp. 1049-1054
  • Oliver, J.J., Webb, D.J., Noninvasive assessment of arterial stiffness and risk of atherosclerotic events (2003) Arteriosclerosis, Thrombosis, and Vascular Biology, 23 (4), pp. 554-566
  • Hirai, T., Sasayama, S., Kawazaki, T., Yagi, S., Stiffness of systemic arteries in patients with myocardial infarction a noninvasive method to predict severity of coronary aterosclerosis (1989) Circulation, 80 (1), pp. 78-86
  • Khamdaeng, T., Luo, J., Vappou, J., Terdtoon, P., Konofagou, E., Arterial stiffness identification of the human carotid artery using the stress-strain relationship in vivo (2012) Ultrasonics, 52 (3), pp. 402-411
  • Nichols, W.W., O'Rourke, M.F., (2005) McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles, , (5th edition), Hodder Arnold, 0340809418, London
  • London, G.M., Pannier, B., Arterial functions: How to interpret the complex physiology (2010) Nephrology, Dialysis, Transplantation, 25 (12), pp. 3815-3823
  • Koelwyn, G.J., Currie, K.D., MacDonald, M.J., Eves, N.D., Ultrasonography and tonometry for the assessment of human arterial stiffness (2012) Applied Aspects of Ultrasonography in Humans, pp. 115-140
  • Paini, A., Boutouyrie, P., Calvet, D., Tropeano, A.I., Laloux, B., Laurent, S., Carotid and aortic stiffness determinants of discrepancies (2006) Hypertension, 47 (3), pp. 371-376
  • Bussy, C., Boutouyrie, P., Lacolley, P., Challande, P., Laurent, S., Intrinsic stiffness of the carotid arterial wall material in essential hypertensives (2000) Hypertension, 35 (5), pp. 1049-1054
  • Patvardhan, E.A., Heffernan, K.S., Ruan, J.M., Soffler, M.I., Karas, R.H., Kuvin, J.T., Assessment of vascular endothelial function with peripheral arterial tonometry (2010) Cardiol Rev, 18 (1), pp. 20-28
  • Bruno, R.M., Gori, T., Ghiadoni, L., Endothelial function testing and cardiovascular disease: Focus on peripheral arterial tonometry (2014) Vascular Health and Risk Management, 10, pp. 577-584
  • Armentano, R.L., Megnien, J.L., Simon, A., Bellenfant, F., Barra, J., Levenson, J., Effects of hypertension on viscoelasticity of carotid and femoral arteries in humans (1995) Hypertension, 26 (1), pp. 48-54
  • De Luca, M.A., Petrauskas, L., Meyer, I., Cymberknop, L.J., Armentano, R.L., Red Inalámbrica de Dispositivos para la medición de parámetros Fisiológicos (2014) IV Congreso Latinoamericano de Ingeniería Biomédica-CLAIB-Entre Ríos, Argentina
  • Armentano, R.L., Levenson, J., Barra, J.G., Fischer, E.I., Breitbart, G.J., Pichel, R.H., Simon, A., Assessment of elastin and collagen contribution to aortic elasticity in conscious dogs (1991) American Journal of Physiology, 260 (6), pp. H1870-1877
  • Lanne, T., Sonesson, B., Bergqvist, D., Bengtsson, H., Gustafsson, D., Diameter and compliance in the male human abdominal aorta: Influence of age and aortic aneurysm (1992) European Journal of Vascular Surgery, 6 (2), pp. 178-184
  • Graf, S., Gariepy, J., Massonneau, M., Armentano, R.L., Mansour, S., Barra, J.G., Simon, A., Levenson, J., Experimental and clinical validation of arterial diameter waveform and intimal media thickness obtained from bmode ultrasound image processing (1999) Ultrasound Med Biol, 25 (9), pp. 1353-1363
  • Armentano, R.L., Cabrera Fischer, E.I., Barra, J.G., Levenson, J.A., Simon, A.C., Pichel, R.H., Single beat evaluation of circumferential aortic elastin elastic modulus in conscious dogs potential application in non-invasive measurements (1994) Med. Prog. Technol., 20 (1-2), pp. 91-99
  • Cymberknop, L.J., Armentano, R.L., Legnani, W., Pessana, F.M., Craiem, D., Graf, S., Barra, J.G., Contribution of arterial tree structure to the arterial pressure fractal behavior (2013) Journal of Physics, 477, pp. 12039-12044
  • Leiva, L., Schiaffi, J., Alfonso, M., Cymberknop, L.J., Armentano, R.L., Análisis del Tiempo de Tránsito del Pulso Arterial por Tonometría: Aplicación en la Comunidad Universitaria (2015) XX Congreso Argentino de Bioingeniería-SABI-Buenos Aires, Argentina
  • Laurent, S., Cockcroft, J., Van Bortel, L., Boutouvrie, P., Giannattasio, C., Havoz, D., Pannier, B., Struijker-Boudier, H., Expert consensus document on arterial stiffness: Methodological issues and clinical applications (2006) Eur Heart J, 27 (21), pp. 2588-2605
  • Simova, I., Katova, T., Kostova, V., Hristova, K., Dimitrov, N., Reproducibility of arterial stiffness indices at different vascular territories (2011) Echocardiography, 28 (4), pp. 448-456
  • Zong, W., Heldt, T., Moody, G.B., Mark, R.G., An open-source algorithm to detect onset of arterial blood pressure pulses (2003) IEEE, pp. 259-262
  • Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., Guidelines for the management of arterial hypertension the task force for the management of arterial hypertension of the european society of hypertension (ESH) and of the european society of cardiology (ESC) (2013) Hypertension, 31 (7), pp. 1281-1357
  • O'Rourke, M.F., Safar, M.E., Relationship between aortic stiffening and microvascular disease in brain and kidney: Cause and logic of therapy (2005) Hypertension, 46 (1), pp. 200-204
  • Arbeitman, C.R., Cymberknop, L.J., Farro, I., Cardelino, J., Armentano, R.L., Vascular reactivity in healthy subjects: Simultaneous characterization of arterial pressure and diameter time profiles (2016) 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC'16)

Citas:

---------- APA ----------
Pérez López, N., De Luca, M.A., Sivori, G., Cymberknop, L.J., Armentano, R.L., Romero E., Lepore N.,..., et al.; Ministerio de Ciencia, Tecnologia e Innovacion Productiva (MinCyT); SIPAIM Foundation; Universidad Nacional de Colombia; Universidad Nacional del Centro de la Provincia de Buenos Aires (UNICEN); Universidad Panamericana (2017) . Real-time vascular response assessment by means of a dual pressure-diameter device: A preliminary study. 12th International Symposium on Medical Information Processing and Analysis, SIPAIM 2016, 10160.
http://dx.doi.org/10.1117/12.2257206
---------- CHICAGO ----------
Pérez López, N., De Luca, M.A., Sivori, G., Cymberknop, L.J., Armentano, R.L., Romero E., et al. "Real-time vascular response assessment by means of a dual pressure-diameter device: A preliminary study" . 12th International Symposium on Medical Information Processing and Analysis, SIPAIM 2016 10160 (2017).
http://dx.doi.org/10.1117/12.2257206
---------- MLA ----------
Pérez López, N., De Luca, M.A., Sivori, G., Cymberknop, L.J., Armentano, R.L., Romero E., et al. "Real-time vascular response assessment by means of a dual pressure-diameter device: A preliminary study" . 12th International Symposium on Medical Information Processing and Analysis, SIPAIM 2016, vol. 10160, 2017.
http://dx.doi.org/10.1117/12.2257206
---------- VANCOUVER ----------
Pérez López, N., De Luca, M.A., Sivori, G., Cymberknop, L.J., Armentano, R.L., Romero E., et al. Real-time vascular response assessment by means of a dual pressure-diameter device: A preliminary study. Proc SPIE Int Soc Opt Eng. 2017;10160.
http://dx.doi.org/10.1117/12.2257206