Artículo

Zócalo, Y.; Pérez Campos, H.; Galli, C.N.; Saldías, M.; Camus, J.M.; Silva, W.; Bia Santana, D.; Álvarez, O.; Álvarez, I.; Armentano, R. "Characterization of the mechanic behavior of the conduits used in the confection of vascular accesses in dialyzed subjects " (2005) Revista de Nefrologia, Dialisis y Trasplante. 25(4):141-146
Estamos trabajando para incorporar este artículo al repositorio
Consulte la política de Acceso Abierto del editor

Abstract:

Intimal hyperplasia development is recognized as the most important cause of vascular access failure in patients submitted renal function replacement therapy. An important factor that affects the development of intimal hyperplasia is elastic mismatch between native vessel and among vein, arteries and the synthetic graft. In this work, a biomechanical analysis of cryopreserved arteries, expanded polytetrafluoroethylene (ePTFE), and fresh arteries and veins is reported. In vitro pressure (Konigsberg) and diameter (Sonomicrometry) were measured in fresh human vein and arteries and cryopreserved human defrosted arteries and ePTFE prosthesis, under isobaric and systemic pressures levels. Our results showed that ePTFE conduits have an elastic index which is significantly different from that of fresh and cryopreserved defrosted arteries and veins. These stiffness differences determine a high elastic mismatch. We conclude that this study of tubular segments to be used as vascular accesses in dialyzed patients, demonstrate significantly elastic differences that could be an important determinant of late access viability.

Registro:

Documento: Artículo
Título:Characterization of the mechanic behavior of the conduits used in the confection of vascular accesses in dialyzed subjects
Autor:Zócalo, Y.; Pérez Campos, H.; Galli, C.N.; Saldías, M.; Camus, J.M.; Silva, W.; Bia Santana, D.; Álvarez, O.; Álvarez, I.; Armentano, R.
Filiación:Departamento de Fisiología, Facultad de Medicina, Universidad de la República, Montevideo, Uruguay
Instituto Nacional de Donación y Trasplante de Células Tejidos y Organos, Facultad de Medicina, Universidad de la República, Montevideo, Uruguay
Departamento de Ingeniería Cardiovascular, Facultad Regional Buenos Aires, Universidad Tecnológica Nacional, Medrano 951, Buenos Aires, Argentina
Facultad de Ingeniería y Ciencias Exactas y Naturales, Universidad Favaloro, Buenos Aires, Argentina
ESFUNO, Facultad de Enfermería, Universidad de la República, Montevideo, Uruguay
Idioma: Español
Palabras clave:politef; arterial pressure; artery diameter; article; biomechanics; blood vessel compliance; blood vessel parameters; controlled study; cryopreservation; elasticity; hemodialysis; hemodialysis patient; human; human tissue; in vitro study; pneumatic tool; politef implant; treatment outcome; ultrasound; vascular access; vein diameter; venous pressure
Año:2005
Volumen:25
Número:4
Página de inicio:141
Página de fin:146
Título revista:Revista de Nefrologia, Dialisis y Trasplante
Título revista abreviado:Rev. Nefrol. Dial. Transplant.
ISSN:03263428
CAS:politef, 9002-84-0, 9039-02-5
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03263428_v25_n4_p141_Zocalo

Referencias:

  • Canaud, B., Venous Accesses for Hemodialysis-Facts and Througts (2004) Business Brieffing: Global Healthcare-Advanced Medical Technologies, pp. 1-5
  • Grigioni, M., Jaffrin, M., Rieu, R., Verdonck, P., (1994) Chapter 6: Artificial Organs. En Cardiovascular Fluid Dynamics Principles and Clinical Applications, pp. 1-22. , Second Ed. France
  • Rodriguez, J.A., Amadans, L., Ferrer, E., Olmos, A., Codina, S., Bartolomé, J., Borrellas, J., Piera, L., The function of permanent vascular access (2000) Nephrol Dial Transplant, 15, pp. 402-408
  • Young, E.W., Dykstra, D.M., Goodkin, D.A., Mapes, D.L., Wolfe, R.A., Held, P.J., Hemodialysis vascular access preferences and outcomes in the Dialyisis Outcomes and Practice Patterns Study (DOPPS) (2002) Kidney International, 61, pp. 2266-2271
  • Mastsuda, H., Miyazaki, M., Oka, Y., Nakao, A., Choda, Y., Kokumai, Y., Kunitomo, K., Tanaka, N., A Polyurethane Vascular Access Graft and Hybrid Polytetrafluoroethylene Graft as an Arteriovenous Fistula for Hemodialysis: Comparison with an Expanded Polytetrafluoroethylene Graft (2003) Artificial Organs, 27 (8), pp. 722-727
  • Tsui, J.C.S., Dashwood, M.R., Recent strategies to reduce vein graft occlusion: A need to limit the effect of vascular damage (2002) Eur J Vasc Endovasc Surg, 23, pp. 202-208
  • Bolton, W., Cull, D., Taylor, S., Carsten, C., Snyder, B., Sullivan, T., Yourkey, J., Gray, B., The use of Cryopreserved femoral vein grafts for hemodialysis access in patients at high risk for infection: A word of caution (2002) J Vasc Surg, 36, pp. 464-468
  • Cabrera-Fischer, E.I., Bia Santana, D., Cassanello, G.L., Zócalo, Y., Craword, E.V., Casas, R., Armentano, R.L., Reduced elastic mismatch achieved by interposing vein cuff in expanded polytetrafluoroethylene femoral bypass decreases intimal hyperplasia (2005) Artificial Organs, 29 (2), pp. 122-130
  • Blacher, J., Guerin, A., Pannier, B., Marchais, S., London, G., Arterial calcifications, arterial stiffness, and cardiovascular risk in end-stage renal disease (2001) Hypertension, 38, pp. 938-942
  • Galli, C., Risk, M., Camus, J., Cabrera Fischer, E., Calcificación arterial y su evaluación funcional en la enfermedad renal crónica (2004) Rev Nefrol Dial Y Transpl, 24 (4), pp. 165-170
  • Galli, C., Camus, J., Cabrera Fischer, E., Risk, M., La velocidad de la onda del pulso en la evaluación vascular de pacientes con insuficiencia renal (2004) Rev Fed Arg Cardiol, 33, pp. 212-217
  • Bia, D., Armentano, R.L., Zócalo, Y., Barmak, W., Migliaron, E., Cabrera Fischer, E.I., In vitro model to study arterial wall dynamics through pressure-diameter relationship analysis (2005) LAAR, 35, pp. 217-224
  • Armentano, R.L., Cabrera Fischer, E.I., Systemic Circulation: Arteries Function (2001) Cardiovascular Failure: Pathophysiological Bases and Management, pp. 73-110. , Fischer EIC, Christen AI, Trainini JC. Chapter 3; Ed: Fundación Universitaria Dr. René Favaloro, Buenos Aires Argentina
  • Takamoto, S., Nakajima, S., Okita, Y., Motomura, N., Yuasa, M., Sada, M., Imakita, M., Tsuji, T., Cryopreserved femoral arterial allografts for vascular access in hemodialysis (1998) Transplant Proc, 30 (7), pp. 3917-3919. , Nov
  • Lin, P.H., Brinkman, W.T., Terramani, T.T., Lumsden, A.B., Management of infected hemodialysis access grafts using cryopreserved human vein allografts (2002) Am J Surg, 184 (1), pp. 31-36. , Jul
  • Madden, R.L., Lipkowitz, G.S., Browne, B.J., Kurbanov, A., Experience with cryopreserved cadaveric femoral vein allografts used for hemodialysis access (2002) Ann Vasc Surg, 18 (4), pp. 453-458. , Jul
  • Roy-Chaudhurry, P., Kelly, B.S., Narayana, A., Desai, P., Melhem, M., Munda, R., Duncan, H., Heffelfinger, S.C., Hemodialysis Vascular Access Dysfunction From Basic Biology to Clinical Intervention (2002) Advanced in Renal Replacement Therapy, 9 (2), pp. 74-84
  • Nguyen, V.D., Griffith, C., Treat, L., Multidisciplinary Team Approach to Increasing AV Fistula Creation (2003) Nephrology News & Issues, pp. 54-62
  • Seifalian, A.M., Tiwari, A., Hamilton, G., Salacinski, H.J., Improving the clinical patency of prosthetic vascular and coronary bypass grafts: The role of seeding and tissue engineering (2002) Artificial Organs, 26 (4), pp. 307-320
  • Joanides, R., Costentin, A., Iacob, M., Bakkali, E.H., Richard, M.O., Thuillez, C., Role of arterial smooth muscle tone and geometry in the regulation of peripheral conduit artery mechanics by shear stress (2001) Clin Exp Pharmacol Physiol, 28, pp. 1025-1031
  • Cabrera Fischer, E.I., Armentano, R.L., Pessana, F.M., Graf, S., Romero, L., Christen, A.I., Simon, A., Levenson, J., Endothelium-dependent arterial wall tone elasticity modulated by blood viscosity (2002) Am J Physiol Heart Circ Physiol, 282, pp. 389-394
  • Hofstra, L., Bergamns, D.C.J.J., Leunissen, K.M.L., Hoeks, A.P.G., Kitslaar, P.J.E.H.M., Daemen, M.J.A.P., Tordoir, J.H.M., Anastomotic Intimal Hyperplasia in Prosthetic Arteriovenous Fistulas for Hemodialysis Is Associated with Initial High Flow Velocity and Not with Mismatch in Elastic Propierties (1995) J Am Soc Nephrol, 6, pp. 1625-1633
  • Safar, M.E., London, G.M., Plante, G.E., Arterial stiffness and kidney function (2004) Hypertension, 43, pp. 163-168
  • Palma, J.L., Métodos no invasivos para la evaluación de las propiedades físicas de las grandes arterias en la hipertensión arterial (2002) Nefrología, 22, pp. 16-20
  • Nitta, K., Akiba, T., Uchida, K., Otsubo, S., Otsubo, Y., Takei, T., Ogawa, T., Nihei, H., Left ventricular hypertrophy is associated with arterial stiffness and vascular calcification in hemodialysis patients (2004) Hypertens Res, 27, pp. 47-52
  • Westerbacka, J., Uosukainen, A., Mäkimattila, S., Schlenzka, A., Yki-Järvinen, H., Insulin-induced decrease in large artery stiffness is impaired in uncomplicated type 1 Diabetes Mellitus (2000) Hypertension, 35, pp. 1043-1048
  • Cohen, D.L., Warburton, K.M., Warren, G., Bloom, R.D., Towsend, R.R., Pulse wave analysis to assess vascular compliance changes in stable renal transplant recipients (2004) Am J Hypertens, 17, pp. 209-212
  • Dobrin, P.B., Mirande, R., Kang, S., Dong, Q.S., Mrkvicka, R., Mechanics of end-to-end artery-to-PTFE grafo anastomoses (1998) Ann Vasc Surg, 12, pp. 317-323

Citas:

---------- APA ----------
Zócalo, Y., Pérez Campos, H., Galli, C.N., Saldías, M., Camus, J.M., Silva, W., Bia Santana, D.,..., Armentano, R. (2005) . Characterization of the mechanic behavior of the conduits used in the confection of vascular accesses in dialyzed subjects . Revista de Nefrologia, Dialisis y Trasplante, 25(4), 141-146.
Recuperado de https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03263428_v25_n4_p141_Zocalo [ ]
---------- CHICAGO ----------
Zócalo, Y., Pérez Campos, H., Galli, C.N., Saldías, M., Camus, J.M., Silva, W., et al. "Characterization of the mechanic behavior of the conduits used in the confection of vascular accesses in dialyzed subjects " . Revista de Nefrologia, Dialisis y Trasplante 25, no. 4 (2005) : 141-146.
Recuperado de https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03263428_v25_n4_p141_Zocalo [ ]
---------- MLA ----------
Zócalo, Y., Pérez Campos, H., Galli, C.N., Saldías, M., Camus, J.M., Silva, W., et al. "Characterization of the mechanic behavior of the conduits used in the confection of vascular accesses in dialyzed subjects " . Revista de Nefrologia, Dialisis y Trasplante, vol. 25, no. 4, 2005, pp. 141-146.
Recuperado de https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03263428_v25_n4_p141_Zocalo [ ]
---------- VANCOUVER ----------
Zócalo, Y., Pérez Campos, H., Galli, C.N., Saldías, M., Camus, J.M., Silva, W., et al. Characterization of the mechanic behavior of the conduits used in the confection of vascular accesses in dialyzed subjects . Rev. Nefrol. Dial. Transplant. 2005;25(4):141-146.
Available from: https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_03263428_v25_n4_p141_Zocalo [ ]