Artículo

Estamos trabajando para incorporar este artículo al repositorio
Consulte el artículo en la página del editor
Consulte la política de Acceso Abierto del editor

Abstract:

We present a novel method to measure precisely the relative spectral response of the fluorescence telescopes of the Pierre Auger Observatory. We used a portable light source based on a xenon flasher and a monochromator to measure the relative spectral efficiencies of eight telescopes in steps of 5 nm from 280 nm to 440 nm. Each point in a scan had approximately 2 nm FWHM out of the monochromator. Different sets of telescopes in the observatory have different optical components, and the eight telescopes measured represent two each of the four combinations of components represented in the observatory. We made an end-to-end measurement of the response from different combinations of optical components, and the monochromator setup allowed for more precise and complete measurements than our previous multi-wavelength calibrations. We find an overall uncertainty in the calibration of the spectral response of most of the telescopes of 1.5% for all wavelengths; the six oldest telescopes have larger overall uncertainties of about 2.2%. We also report changes in physics measurables due to the change in calibration, which are generally small. © 2017 Elsevier B.V.

Registro:

Documento: Artículo
Título:Spectral calibration of the fluorescence telescopes of the Pierre Auger Observatory
Autor:Aab, A. et al.
Este artículo contiene 404 autores, consultelos en el artículo en formato pdf.
Filiación: Este artículo contiene 404 autores con sus filiaciones, consultelas en el artículo en formato pdf.
Palabras clave:Auger observatory; Calibration; Extensive air shower; Nitrogen fluorescence; Augers; Calibration; Fluorescence; Light sources; Monochromators; Observatories; Auger observatory; End-to-end measurement; Extensive air showers; Fluorescence telescopes; Pierre Auger observatory; Relative spectral response; Spectral calibration; Spectral efficiencies; Telescopes
Año:2017
Volumen:95
Página de inicio:44
Página de fin:56
DOI: http://dx.doi.org/10.1016/j.astropartphys.2017.09.001
Título revista:Astroparticle Physics
Título revista abreviado:Astropart. Phys.
ISSN:09276505
CODEN:APHYE
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_09276505_v95_n_p44_Aab

Referencias:

  • Aab, A., The Pierre Auger cosmic ray observatory (2015) Nuclear Instrum. Methods Phys. Res. Sect. A, 798, pp. 172-213
  • Allekotte, I., The surface detector system of the pierre auger observatory (2008) Nuclear Instrum. Methods Phys. Res. Sect. A, 586 (3), pp. 409-420
  • Abraham, J., The fluorescence detector of the Pierre Auger observatory (2010) Nuclear Instrum. Methods Phys. Res. Sect. A, 620 (2-3), pp. 227-251
  • Mathes, T.H.-J., The HEAT telescopes of the Pierre Auger observatory status and first data (2011) Proc. of the 32 nd ICRC, Beijing, China, pp. 153-156
  • Roth, M., Measurement of the UHECR energy spectrum using data from the surface detector of the Pierre Auger Observatory (2007) Proc. of the 30 th ICRC, Mérida, Mexico
  • Abraham, J., Observation of the suppression of the flux of cosmic rays above 4 × 10 19  ev (2008) Phys. Rev. Lett., 101, p. 061101
  • Brack, J., Absolute calibration of a large-diameter light source (2013) JINST, 8, p. P05014
  • Knapik, R., The absolute, relative and multi-wavelength calibration of the Pierre Auger observatory fluorescence detectors (2007) Proc. of the 30 th ICRC, Mérida, Mexico
  • Rovero, A., Bauleo, P., Brack, J., Harton, J., Knapik, R., Multi-wavelength calibration procedure for the pierre auger observatory fluorescence detectors (2009) Astropart. Phys., 31 (4), pp. 305-311
  • Ave, M., Spectrally resolved pressure dependence measurements of air fluorescence emission with AIRFLY (2008) Nuclear Instrum. Methods Phys. Res. Sect. A, 597 (1), pp. 41-45
  • Matthews, J.A., Optical calibration of the auger fluorescence telescopes (2003) Astronomical Telescopes and Instrumentation, pp. 121-130. , International Society for Optics and Photonics
  • Aab, A., The Pierre Auger observatory: contributions to the 33rd international cosmic ray conference (ICRC 2013) arXiv: 1307.5059; Brack, J., Meyhandan, R., Hofman, G., Matthews, J., Absolute photometric calibration of large aperture optical systems (2004) Astropart. Phys., 20 (6), pp. 653-659
  • Aramo, C., Optical relative calibration and stability monitoring for the auger fluorescence detector (2005) Proc. of the 29th ICRC, Pune, India
  • Abraham, J., Properties and performance of the prototype instrument for the pierre auger observatory (2004) Nuclear Instrum. Methods Phys. Res. A, 523, pp. 50-95
  • Argiró, S., The offline software framework of the Pierre Auger observatory (2007) Nuclear Instrum. Methods Phys. Res. Sect. A, 580 (3), pp. 1485-1496

Citas:

---------- APA ----------
(2017) . Spectral calibration of the fluorescence telescopes of the Pierre Auger Observatory. Astroparticle Physics, 95, 44-56.
http://dx.doi.org/10.1016/j.astropartphys.2017.09.001
---------- CHICAGO ----------
Aab, A. "Spectral calibration of the fluorescence telescopes of the Pierre Auger Observatory" . Astroparticle Physics 95 (2017) : 44-56.
http://dx.doi.org/10.1016/j.astropartphys.2017.09.001
---------- MLA ----------
Aab, A. "Spectral calibration of the fluorescence telescopes of the Pierre Auger Observatory" . Astroparticle Physics, vol. 95, 2017, pp. 44-56.
http://dx.doi.org/10.1016/j.astropartphys.2017.09.001
---------- VANCOUVER ----------
Aab, A. Spectral calibration of the fluorescence telescopes of the Pierre Auger Observatory. Astropart. Phys. 2017;95:44-56.
http://dx.doi.org/10.1016/j.astropartphys.2017.09.001