Artículo

Estamos trabajando para incorporar este artículo al repositorio
Consulte la política de Acceso Abierto del editor

Abstract:

In this study we have performed a comparison of the most used spectroscopic glucose-oxidase assay for routine clinical monitoring of serum glucose, with the high-performance anion-exchange chromatographic method using pulsed amperometric detection (HPAEC-PAD). The linearity, repeatability and internal reproducibility of the chromatographic method were determined. The correlation by linear regression and difference plot was analyzed. It is known that the enzymatic method leads to unreliable results when glucose must be determined in samples containing high concentration of bilirubin or lipids. On the contrary, the accuracy of the HPAEC-PAD method with these complex matrix sera resulted similar to normal samples showing no interferences. Another advantage was the minimal amount of human serum needed: one microliter was largely sufficient to perform the whole analysis. This fact would make the HPAEC-PAD method applicable when samples of preterm infants or new born babies of low weight must be analyzed. ©ARKAT.

Registro:

Documento: Artículo
Título:Comparison of micro-enzymatic and high performance anion exchange chromatography methods for the analysis of glucose in human serum
Autor:Casabuono, A.C.; Moirón, M.D.C.; Buchta, C.; Perego, M.D.C.; Couto, A.S.
Filiación:CIHIDECAR-CONICET, Depto. de Química Orgánica, 3P Ciudad Universitaria, 1428 Buenos Aires, Argentina
Hospital Materno Infantil Ramón Sardá, Secretaría de Salud, G.C.B.A, Argentina
Palabras clave:Glucose determination; Glucose-oxidase method; HPAEC-PAD; Human serum analysis
Año:2006
Volumen:2005
Número:12
Página de inicio:243
Página de fin:252
Título revista:Arkivoc
Título revista abreviado:Arkivoc
ISSN:14246376
Registro:https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_14246376_v2005_n12_p243_Casabuono

Referencias:

  • Somogyi, M., (1952) J. Biol. Chem., 195, p. 19
  • Ceriotti, G., Frank, A.D.N., (1969) Clin. Chim. Acta, 24, p. 311
  • Kaplan, L.A., Pesce, A., (1984) J.Clinical Chemistry, Theory Analysis and Correlation, , at Louis the C.V. Mosby Co
  • Slein, M.W., (1965) Methods of Enzymatic Analysis, p. 117. , H.-U. Bergmeyer, Ed. Academic Press: New York, N.Y
  • Mager, M., Farese, G., (1965) Tech. Bull. Regist. Med. Technol., 35, p. 104
  • Wright, W.H., Rainwater, J.C., Tolle, L., (1971) Clin. Chem., 17, p. 1010
  • Trinder, P., (1969) Ann.Clin. Biochem., 6, p. 24
  • Trinder, P., (1975) Ann. Clin. Biochem, 21, p. 1754
  • Gerson, B., Figoni, M., (1985) Arch Pathol Lab. Med., 109, p. 711
  • Rocklin, R.D., Pohl, C.A., (1983) J. Liq. Chromatogr., 6, p. 1577
  • Chaplin, M.F., (1982) Analytical Biochem., 123, p. 336
  • Blakeney, A.B., Harris, P.J., Henry, R.J., Stone, B.A., (1983) Carbohydr. Res., 113, p. 291
  • Anumula, K.R., Taylor, P.B., (1992) Analytical Biochem., 203, p. 101
  • Bartolozzi, F., Bertazza, G., Bassi, D., Cristoferi, G., (1997) J. of Chromatogr. A, 758, p. 99
  • Yachida, Y., Tsuchihashi, K., Gasa, S., (1997) Carbohydr. Res., 298, p. 201
  • Akanuma, H., Ogawa, K., Ying-Shih, L., Akanuma, Y., (1981) J. Biochem, 90, p. 157
  • Ball, G.F.M., (1990) Food Chem., 35, p. 117
  • Macrae, R., (1991) Adv. Carbohydr. Anal., 1, p. 293
  • Huges, S., Johnson, D.C., (1981) Anal. Chim. Acta., 132, p. 11
  • Huges, S., Johnson, D.C., (1982) J. of Agric. Food Chem., 30, p. 712
  • Cataldi, T.R.I., Margiotta, G., Zambonin, C.G., (1998) Food Chem., 62, p. 109
  • Lee, Y.C., (1990) Anal Biochem., 189, p. 151
  • Bland, J.M., Altman, D.G., (1986) The Lancet, 327, p. 307

Citas:

---------- APA ----------
Casabuono, A.C., Moirón, M.D.C., Buchta, C., Perego, M.D.C. & Couto, A.S. (2006) . Comparison of micro-enzymatic and high performance anion exchange chromatography methods for the analysis of glucose in human serum. Arkivoc, 2005(12), 243-252.
Recuperado de https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_14246376_v2005_n12_p243_Casabuono [ ]
---------- CHICAGO ----------
Casabuono, A.C., Moirón, M.D.C., Buchta, C., Perego, M.D.C., Couto, A.S. "Comparison of micro-enzymatic and high performance anion exchange chromatography methods for the analysis of glucose in human serum" . Arkivoc 2005, no. 12 (2006) : 243-252.
Recuperado de https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_14246376_v2005_n12_p243_Casabuono [ ]
---------- MLA ----------
Casabuono, A.C., Moirón, M.D.C., Buchta, C., Perego, M.D.C., Couto, A.S. "Comparison of micro-enzymatic and high performance anion exchange chromatography methods for the analysis of glucose in human serum" . Arkivoc, vol. 2005, no. 12, 2006, pp. 243-252.
Recuperado de https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_14246376_v2005_n12_p243_Casabuono [ ]
---------- VANCOUVER ----------
Casabuono, A.C., Moirón, M.D.C., Buchta, C., Perego, M.D.C., Couto, A.S. Comparison of micro-enzymatic and high performance anion exchange chromatography methods for the analysis of glucose in human serum. Arkivoc. 2006;2005(12):243-252.
Available from: https://bibliotecadigital.exactas.uba.ar/collection/paper/document/paper_14246376_v2005_n12_p243_Casabuono [ ]